Single Door Door Configuration With S-EIDC-U

Chapter 4: Wiring Connections And Configurations

Single Door Door Configuration With S-EIDC-U

Optional

S-PCON-U

Power Connector

To Ethernet Hub

Ethernet

ConnectionBuilt-in

Infrared Tamper

Note: Maglock is required to have additional external UL listed power supply.

Door Strike

Door Contact S-EIDC-UManual backgroundManual backgroundManual background

Card Reader

or Keypad

To Reader LED Output

Manual background Output 1

Output 2

Input 1

Common

Input 2

Card Reader

IN

Power

Output 1

Output 3 - NC

Common

Output 3 - NO

Input 3

Common

Input 4

Card Reader

OUT

Power

Output 2

Electro-magnetic

Lock

Card Reader

or Keypad

Optional External

Power Supply

24 vDC, 1 Amp

24V DC IN

Built-in

Warning Buzzer

Reader LED Output

Reader Buzzer Output

S-EIDC-U

CAT 5/6

To Ethernet Hub

(PoE Switch)

Note: The S-EIDC-U device and its UL listed Power Supply must be installed within the protected area (locked area) of the access facility to meet UL requirements.

Note: To meet UL requirements, listed panic hardware must be used to allow emergency exit from the protected area.