S-EIDC-U Wiring Terminals

Chapter 4: Wiring Connections And Configurations

S-EIDC-U Wiring Terminals

Output 1

+

Output 2

Input 1

Common

Input 2

Card Reader

IN

Power

OutPut 1

24V DC IN

Output 3 - NC

Common

Output 3 - NO

Input 3

Common

Input 4

Card Reader

Out

Power

Output 2

Reader LED Output

Reader Buzzer Output

The following circuit connections on the S-EIDC-U must occur in a “protected area” to meet UL requirements. A protected area is defined as being within the locked area of the access facility.

Input Power

Outputs

 

 

PW1+

OC1

 

 

PW1-

+

 

 

 

 

OC2

 

 

Relay Inputs

Relay Outputs

 

 

IN1

 

NC

 

 

C

C

 

 

IN2

NO

 

 

IN3

 

 

 

C

 

 

 

IN4

 

 

Input “C” is DC common or ground.

Relay Outputs “NC,” “C,” and “NO” must be connected to a lock within the same room to meet UL requirements.

Output “C” is common between the “NC” and “NO” contact on the relay. For example, if the relay is energized “NO” is connected to “C” and “NC” is not.

Intelli-M Hardware Installation And Reference Guide

27

Page 27
Image 27