Resetting An S-EIDC-U

Chapter 2: S-EIDC-U (ethernet Integrated Door Controller)

Resetting An S-EIDC-U

To perform a hardware reset of an S-EIDC-U, perform the following steps:

Step 1: Disconnect power from the S-EIDC-U. Refer to the Powering Up An S-EIDC-Usection above to see the possible power connections.

Step 2: Disconnect any wiring that may be connected at Input 2 and at BUZ. Then place a jumper at Input 2 and BUZ (that is, connect the Input 2 terminal to the BUZ terminal with a wire.)

Step 3: Reconnect power to the S-EIDC-U, and then after about 3 or 4 seconds remove the jumper (without removing power) that connects the Input 2 terminal to the BUZ terminal.

Step 4: Wait for the LEDs to start flashing the IP address sequence. (You may have to wait up to 5 minutes before the flashing occurs.) Once the LEDs start to flash, recycle power to the S-EIDC-U by disconnecting the power to the S-EIDC-U and then reconnecting the power.

Once Step 4 has been performed, the reset procedure is complete and the S-EIDC-U will have been restored to its factory default.

Quick Mount Assembly

The S-EIDC-U fits in any standard double-gang box, and simply clicks into the mounting plate.

Note: To meet UL requirements, unauthorized access of the Quick Mount Assembly is not permitted.

Quick Mount Assembly Breakdown