6 COORDINATES
General pictures of measurement
Any desired Target coordinates can be determined and stored by setting a Station Point as an original point and inputting the Backsight coordinate in COORDINATES measurement. The coordinates values from Original coordinates point can be determined by the Station coordinates input even if the Station Point is not set as original point. Coordinates values input can be omitted by designating the Station Point No. whenever the Station coordinates are stored in the internal memory.
General pictures
Z
N
Target
Backsight Point
Target
Station Point
E
Detailed Operating procedures
Access the COORDINATES according to " ACCESSING THE SPECIAL FUNCTIONS ".
1. JOB NAME
(1) JOB NAME input | ( Selection keys: ⇐ , ⇒ , ⇑ , ⇓ | ) |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
| 1.JOB NAME | ENT | COORDINATE JOB NAME INPUT | |||||||
|
|
|
|
|
|
| ||||
|
| JOB NAME input by pressing selection keys | ENT |
(2)JOB NAME selection ( Selection keys: ∆ , ∇ , ⇑ , ⇓ )
1. JOB NAME |
| ENT |
| COORDINATES JOB NAME INPUT |
ENT
SelecttheJOBNAMEby shiftkeys
ENT
Totheprimary screenoftheCOORDINATES
The JOB NAME can be selected only when the JOB NAMES are already stored.