I/O Channel Control Commands
152 IOLAN SDS/SCS/STS CLI Reference Guide, Version 3.6

Show IO

Show IOChannel

I/O Channel Control Commands
The I/O commands in this section are used to manually manage the I/O channels.

Digital Output

Description Shows global I/O information (for example, UDP, TruePort, Modbus). Temperature I/O
is Analog.
User Level Admin
Syntax show iochannel <i/o_channel>
show iochannel rts|cts|dtr|dsr|dcd
Options i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
rts|cts|dtr|dsr|dcd
Specify the Digital output pins (RTS or DTR) or Digital input pins (CTS, DSR, or
DCD).
Description Shows I/O channel information. Temperature I/O is Analog.
User Level Admin
Syntax show iochannel <i/o_channel>
show iochannel line <number> rts|cts|dtr|dsr|dcd
Options i/o_channel
Specify the channel number, for example, d2 or a4. Temperature models use Analog
input, so the channel numbers are a1-a4.
rts|cts|dtr|dsr|dcd
Specify the Digital output pins (RTS or DTR) or Digital input pins (CTS, DSR, or
DCD).
Description Manages the Digital output channel status. Not all models have four Digital channels,
most have just two.
User Level Admin
Syntax iochannel d1|d2|d3|d4|cts|dsr|dcd clear alarm|input-latch
Options alarm
Clears the alarm. Note that if the condition that tripped the alarm still exists, the alarm
will not look like it’s cleared, but will reflect the appropriate alarm level severity.
Alarm Level 0 means that the alarm has not been triggered.
latch-input
Clears the latch value.