SNMP
32 IOLAN Device Server User’s Guide, Version 1.0
The first variable in each folder is the Status variable, for example, serviceStatus. When you
perform a GET on this variable, one of the following values will be returned:
z1—Indicates that the container folder is active with no changes.
z2—Indicates that the container folder is active with change(s).
Once you have completed setting the variables in a folder, you will want to submit your changes to
the Device Server. To do this, set the Status variable to 4. If you want to discard the changes, set the
Status variable to 6.
z4—Indicates that the changes in the container folder are to be submitted to the Device Server.
z6—Indicates that the changes in the container folder are to be discarded.
If you want to save all the changes that have been submitted to the Device Server, you need to
expand the adminInfo container folder and SET the adminFunction to 1 to write to FLASH. To
make the configuration changes take effect, SET the adminFunction to 3 to reboot the Device Server.