SPD-(Copper Port 1/2)

Green – 1000 Mbps

Orange – 100 Mbps

Off – 10 Mbps (if link is currently established)

FDC-1/2 (Duplex on Copper 1/2)

On – Full Duplex Mode

Off – Half Duplex Mode

LKC-1/2 (Link Status on Copper port 1/2)

On – Copper link is present

Off – No copper link present

Blinking (slow) – Copper link appears functional – Copper link has been brought down by Smart Link Pass-Through.

Blinking (fast) – Copper link up and receiving data

PSE-1/2

Solid Green (Active) – The PSE has successfully detected a compliant PD and is applying power over the UTP.

Solid Orange (Inactive) – The PSE is not active. The PSE has been configured to provide power, however

a compliant PD is not detected - no power applied

a PSE has turned off power for Reset function

Off – (Disabled) The PSE function is disabled in the configuration.

Error conditions

A blinking red light is an error condition. The led light will cycle with a 3 second stop interval between the error condition code.

PSE-1 / 2 LED

 

1 blink

PD Capacitance too high

2 blinks

PD Resistance too low or short circuit

3 blinks

PD Resistance too high

20