Installing the Copper Cable

1.Locate 10/100/1000Base-T compliant copper cables with the appropriate connectors.

2.Connect the RJ-45 cable between the Perle media converter and the device.

Note: The Perle media converter supports Auto-MDIX which allows connection of a straight-through or cross-over Ethernet cable. See Auto-MDIX Jumper Settings in this guide for jumper positions.

Grounding the Media Converter

If your installation requires additional grounding the following procedure can be followed.

Grounding the chassis requires the following items:

One grounding lug (not provided).

One 18 - 12 AWG wire (not provided).

Cross-head screwdriver (not provided).

Note: For your safety, when installing this equipment, always ensure that the chassis ground connection is installed first and disconnected last.

Attaching the Grounding Lug

1. Attach the grounding lug to one end of an 18-12 AWG wire.