Mechanical Instructions

L06.1E

 

4.

 

EN 11

4.4.4Large Signal Panel (LSP)

1

4.5Set Re-assembly

To re-assemble the whole set, do all processes in reverse order.

Be sure that, before the rear cover is mounted:

The mains cord is postioned correctly in its guiding brackets (make sure that the strain relief will function correctly!).

All wires/cables are returned in their original positions. This is very important, in view of the “hot” and “EHT” areas of the set.

Check if no wires are touching the heat sinks that are on the LSP; this may dammage the cables!

G_16350_045.eps 060406

Figure 4-7 LSP locking handles

1.Simultanuously do the following:

a.Pull the two plastic locking handles at the mid left and mid right side of the bracket gently backwards to unlock the bracket (see Figure “LSP locking handles”), and

b.Loosen the bracket from the bottom tray, by pulling it backwards.

N.B.: You do not need to pull the other two locking handles backwards.

2.Remove the LSP-bracket from the bottom tray by lifting it upwards.

3.Remove all cables from the LSP.

4.Remove the board from the bracket by unhooking it from its fixation clamps.

Page 11
Image 11
Philips L06.1E AA technical specifications Set Re-assembly, LSP locking handles