Orion/2 Outdoor

M.E.

The item is a standard mechanical operation. As the dome tilts 90°, it will pan 180°, then continuing tilt to keep tracking object.

OFF

Select this item to disable the flip function.

NOTE: The dome will only be able to tilt 90°, or -10° ~100° with angle adjuster adjustments.

ZOOM SPEED

This item is used to set the zoom speed for operating the dome camera.

26x Model:

For these models, the zoom speed options are <1> (slow) ~ <8> (fast). The default is <8>.

22/23x Model:

For the two models, the options are <FAST> and <SLOW> (default).

SPEED BY ZOOM

If the item is set to <ON>, the pan/tilt speed will be adjusted by internal algorithm when zooming automatically. The larger zoom ratio leads the lower rotation speed.

AUTO CALIBRATION

There are one horizontal and one vertical infrared rays check points in each dome. When the dome camera position may be moved during installation or maintenance, the relative distance between the original set point and the check point has been changed. Enable the Auto Calibration function, the dome will automatically detect that and reset the point back to the original position.

DIGITAL ZOOM

With this item, users can enable or disable the 12× Digital Zoom. The Digital Zoom activate after the full Optical Zoom level is reached.

NOTE: The difference between optical and digital zoom is that optical zoom uses the lens within the camera to draw the image closer via zoom in or out to achieve the desired effect. Optical zoom remains the same and the full resolution of the zoomed image quality. On the other hand, Digital zoom takes a portion of image and expands that image to the full size of the image; however the image quality will be reduced.