ALARM SETTING

 

ALARM PIN

1

ALARM SWITCH

OFF

ALARM TYPE

N.C.

ALARM ACTION

PRESET

PRESET POINT

001

DWELL TIME

ALWAY

EXIT

YES

ALARM PIN

The dome provides 8 alarm inputs and 2 outputs (1× N.O. and 1× N.C.). Select an alarm connector which you want to set its alarm-related parameters with this item, and then set its alarm-related parameters in Alarm Setting menu. For alarm pin definitions, please refer to section 2.6 Alarm Pin Definition or installation guide.

ALARM SWITCH

The item is used to enable or disable the selected alarm pin function. Use the left/right direction keys on the control keyboard to change the setting.

ALARM TYPE

There are two kinds of alarm types: Normal Open and Normal Close, which are illustrated as below. Select an alarm type that corresponds with the alarm application.

ALARM ACTION

Select one of these modes that choose a kind of actions that should be executed when an alarm is triggered. The alarm actions can be set to execute the preset position, sequence, auto-pan or cruise function. Use the right direction key of the control keyboard to change the setting, and the bellowing items will change in cooperating with your selection.

PRESET

Select a preset point where the dome should go when an alarm pin is triggered. The Preset points can be set by a control keyboard.