Orion/2 Outdoor

SEQUENCE

 

SEQUENCE LINE

1

SEQUENCE POINT

01

PRESET POSITION

001

SPEED

1

DWELL TIME

001

RUN SEQUENCE

ENTER

EXIT

YES

SEQUENCE LINE

There are eight sets of sequence lines built in the dome camera. Using LEFT/RIGHT direction keys to select a line first and then set its sequence points.

SEQUENCE POINT

Up to 32 points can be specified for each sequence line. The sequence points represent the orders of the preset points that the dome will automatically run, and the bellowing setup items; PRESET POSITION, SPEED, and DWELL TIME, are related to this item.

PRESET POSITION

Users can assign a specific preset position to the selected sequence point with this item.

SPEED

Users can set the Speed that the dome goes to the next sequence point, and the setup speed range is from 1 ~ 15. Refer to below table for more information.

 

PAN (degree/sec.)

TILT (degree/sec.)

Speed 1

10

8

Speed 2

23

12

Speed 3

35

22

Speed 4

45

30

Speed 5

55

40

Speed 6

65

50

Speed 7

75

58

Speed 8

185

185

Speed 9

205

210

Speed 10

225

240

Speed 11

250

275

Speed 12

280

305

Speed 13

320

335

Speed 14

365

365

Speed 15

400

400