Philips Orion/2 manual Dwell Time RUN Sequence, Autopan Line, Start Point

Models: Orion/2

1 55
Download 55 pages 39.21 Kb
Page 36
Image 36

Orion/2 Outdoor

DWELL TIME

The DWELL TIME is the duration time that the dome will stay at the sequence point, and the range is from <0> to <127> seconds. The dome will go to the next sequence point when the DEWEL TIME is up. If the setting is <0>, the dome will stay at this sequence point until users manually move the dome.

RUN SEQUENCE

User can command the dome camera to run the selected Sequence line manually.

EXIT

Select the item to exit the SEQUENCE menu.

3.3.15AUTOPAN

Auto-pan means rotating or scanning side-to-side motion by a dome camera to view an area horizontally. The parameters can be set on this page.

AUTOPAN

 

AUTOPAN LINE

1

START POINT

TO FIND

END POINT

TO FIND

DIRECTION

RIGHT

SPEED

1

RUN AUTOPAN

ENTER

EXIT

YES

AUTOPAN LINE

There are four sets of auto-pan lines built in dome camera. Users can choose a line to execute using LEFT/RIGHT direction keys. Users are able to command the dome camera to do continuously panning without limit by setting the start point the same as endpoint.

START POINT

Follow the description to set the start position of the AUTOPAN path.

1.Move the cursor to <START POINT> and press <ENTER> while <TO FIND> item flashes, the item will turn <TO SAVE> automatically.

2.Move the dome to a desired position and press <ENTER> to save the position as the start point; the cursor will move to <END POINT> automatically. Ensure to set the end point to complete the auto-pan setting.

NOTE: The tilt and zoom value of the start point will be recorded and fixed for the selected auto-pan line.