47
En
06
About the external synchronizing function
With this unit, the video output signal can be synchronized with NTSC/PAL signals or HD tri-level synchronizing signals
(external synchronizing signals) (External Sync function). This makes it possible to set the timing without connecting
a TBC (time base corrector) or other such device, so the picture can be switched without being disturbed.
• To use the external sync function, set External Sync to On (page 45).
• When using the external sync function, set the external synchronizing signal, playback file format and Scaler
Setting resolution to the same settings (page 45).
• When using the external sync function, use one of the following formats:
720 x 480/59.94i, 720 x 576/50i, 1280 x 720/50p, 1280 x 720/59.94p, 1920 x 1080/50i, 1920 x 1080/59.94i
• The external sync function does not work if Memory 1, Memory 2 or Memory 3 is selected at Video Settings.
Select Standard when using the picture quality adjustment function (page 44).
•The VIDEO OUT terminal has a fixed NTSC or PAL output. The external sync function cannot be used with this
terminal.
To synchronize one player
Set the 75 (terminating switch) on this unit’s rear panel to ON.
To synchronize two or more players with a sync generator
Set the terminal player’s 75 (terminating switch) to ON, the 75 (terminating switches) of the other players to OFF.
Caution
• Does not lock to the external synchronizing signal’s subcarrier component.
• The picture output from the VIDEO OUT, COMPONENT VIDEO OUT and HDMI OUT terminals will be disturbed
for about 30 seconds until locking to the external synchronizing signal.
• Input the external synchronizing signal before playing. Synchronizing is not possible if the signal is input after
playback starts.
• Depending on the sync generator and cables, the external synchronizing signal ma y be attenuated when multiple
players are connected, and this may keep the external sync function from operating.
• The external sync function synchronizes with the video signal’s waveform, not with the timing of the picture. To
synchronize with the picture, use a separate controller.
EXT SYNC IN
ON
75
OFF
EXT SYNC IN
ON
75
OFF
EXT SYNC IN
ON
75
OFF
ON OFF OFF
0009V-DH0009V-DH0009V-DH
Sync generator
2nd unitTerminal 1st unit