6. ADJUSTMENT
6.1 AMP UNIT ADJUSTMENT
A
The items for adjusting AMP unit are:
1Offset Voltage
2Idling Voltage
Refer to the 126 pages for connection of the system at the time of adjustment and repair. Both items are adjustable if the bottom plate of the product is removed to expose the unit. Adjustment is capable using
into a hole on the base plate from its surface B.
When adjusting offset
BConnecting Diagram for AMP Unit
[Offset Voltage/Idling Current Adjustment and Confirmation]
|
| Q1119 |
|
| AMP Unit |
|
| 2SC4886 |
|
| |
|
|
|
|
| |
|
| CN45 |
|
| CN1101 |
Voffset | Iidle | R1129 |
|
| |
|
| 0.1 | CN48 | CN50 | |
|
|
| CN49 | 3 | |
|
| R1130 | CN69 | ||
|
|
|
|
| |
VR1101 | VR1102 | 0.1 | CN83 | CN85 | |
1k | 2.2k | CN46 | |||
C |
|
| CN84 | 4 | |
|
| CN86 | |||
|
| Q1120 |
|
|
|
|
| 2SA1860 | 0 |
| 2 |
|
|
|
| ||
|
|
|
|
| 1 |
4ohm load
Remarks |
| ||
1 | When adjusting and confirming the offset voltage/idling current, connect 4 load to the speaker output | ||
D | terminal. | ||
Input must be | |||
2 | |||
3 | For adjusting offset voltage, coarsely control with VR1101, VR1201, VR1301, VR1401 | ||
| immediately after powering ON, within 3 or 4 minutes. | ||
| Idling current must also be coarsely adjusted at the same time. | ||
4 | Idling current must be adjusted with VR1102, VR1202, VR1302, VR1402 immediately after | ||
| the completion of offset voltage adjustment (within 4 or 5 minutes after powering ON). | ||
5 | Both adjustments must be completed within 3 to 5 minutes after powering ON. | ||
6 | For confirming, measure "within 3 to 5 minutes" after powering ON. | ||
7 | Measuring points for Rated Value No.13 (offset voltage) | ||
| AL | ||
| AR | ||
E | BL | ||
| BR |
8Measuring points for Rated Value No.14 (idling current) AL
AR
F
Postscript) The voltage between R1129 and R1130 as shown in the above diagram
is to be measured so as to adjust the idling current in: |
|
*When mounted on main Main Heat Sink | ) |
*When not mounted on main Main Heat Sink | 0.2 ) |