61
Table7. Weights and Dimensions
UPS ExtendedBattery Module
Dimensions
(WxDxH) 43.2×60.7 ×8.9 cm
17.0×23.9×3.5(2U)
43.2×60.7 ×8.9 cm
17.0×23.9×3.5(2U)
Weights 37kg (81.5 lb) 42.5kg (93 lb)
Table8. Environmental and Safety
120VModels 208VModels 230VModels
OperatingTemperature 0°Cto 40°C (32°F to 104°F)
Optimalbattery performance: 25°C(77°F)
StorageTemperature 0°Cto 25°C (32°F to 77°F)
TransitTemperature -25°Cto 55°C (-13°F to 131°F)
RelativeHumidity 5–95%noncondensing
OperatingAltitude Up to 3,000 meters above sea level
TransitAltitude Up to 10,000 meters above sea level
AudibleNoise Lessthan 45 dBA Normal mode, typical load
Lessthan 50 dBA Battery mode
SurgeSuppression IEEEC62.41 Category B IEEEC62.41 Category B
IEC61000-4-5
IEC61000-4-5
SafetyConformance UL1778, UL 497A
CSAC22.2, No. 107.1, 107.2
NOM-019-SCFI
UL1778, UL 497A
NOM-019-SCFI
IEC60950-1; EN 62040-1-1
IEC60950-1; EN 62040-1-1
AgencyMarkings cULus,NOM-NYCE cULus,NOM-NYCE, CE,
TÜV-GS(G models only)
CE,TÜV-GS
EMC(Class A) FCCPart 15, ICES-003 FCC Part 15, ICES-003 EN 50091-2, IEC 62040-2