SAFETY WARNINGS

C A U T I O N

SBatteries can present a risk of electrical shock or burn from high short-circuit current. Observe proper precautions. Servicing should be performed by qualified service personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from batteries.

SProper disposal of batteries is required. Refer to your local codes for disposal requirements.

SNever dispose of batteries in a fire. Batteries may explode when exposed to flame.

Sikkerhedsanvisninger

VIGTIGE SIKKERHEDSANVISNINGER

GEM DISSE ANVISNINGER

DENNE BRUGERVEJLEDNING INDEHOLDER VIGTIGE

SIKKERHEDSANVISNINGER

F A R E

Denne UPS indeholder LIVSFARLIG HØJSPÆNDING. Alle reparationer og vedligeholdelse bør kun udføres af en AUTORISERET SERVICETEKNIKER. Ingen af UPS’ens indvendige dele kan repareres af brugeren.

A D V A R S E L !

SDenne UPS indeholder egen energiforsyning (batterier). Udgangsnetstikkene kan lede strøm, selv når UPS’en ikke er tilsat en AC-energikilde.

SNetledningen må ikke fjernes og stikket må ikke trækkes ud, mens UPS’en er tændt. Dette fjerner sikkerhedsjorden fra UPS’en og fra det udstyr, der er sat til.

SInstallér denne UPS i et temperatur- og fugtighedskontrolleret indendørsmiljø, frit for ledende forureningsstoffer for at formindske risikoen for brand og elektrisk stød. Rumtemperaturen må ikke overstige 40°C. UPS’en bør ikke betjenes nær vand eller høj fugtighed (maksimalt 95%).

SI overensstemmelse med internationale normer og bestemmelser for el-installation må det udstyr, der er forbundet til udgangen af denne UPS, tilsammen ikke overskride en jordafdelingsspænding på mere end 1,5 milliampere.

SFor UPS systemer med hårdledningsudgange, skal overstrømsbeskyttelse for vekslestrømmens udgangskredsløb forsynes af andre.

SFor UPS systemer med hårdledningsudgange, skal egnede, nominelle afbryderkontakter for vekslestrømmens udgangskredsløb forsynes af andre.

4EATON Powerware® 9125 Two-in-One UPS (2500/3000 VA) User’s Guide S 164201374 Rev D www.powerware.com

Page 10
Image 10
Powerware 2500 manual U T I O N, Sikkerhedsanvisninger, R E

2500 specifications

The Powerware 2500 is a robust uninterruptible power supply (UPS) designed to meet the power protection needs of critical infrastructure in various environments. This industrial-grade UPS is particularly renowned for its reliability, scalability, and versatility, making it a preferred choice for data centers, telecommunications, and healthcare facilities.

One of the most notable features of the Powerware 2500 is its high efficiency. With an efficiency rating often exceeding 95%, the UPS minimizes energy consumption and operational costs, positioning itself as an environmentally friendly solution. This is especially crucial for organizations seeking to reduce their carbon footprint while ensuring continuous power supply.

The Powerware 2500 utilizes advanced technologies such as double-conversion online design, which ensures that connected equipment receives a consistent and clean power supply regardless of input voltage fluctuations or outages. This technology effectively isolates critical loads from grid disturbances, enhancing the reliability of sensitive electronics and critical operational tasks.

Another key characteristic of the Powerware 2500 is its scalability. Designed with modular capabilities, it allows businesses to easily expand their power protection solutions as their requirements grow. This feature ensures that organizations are not forced to invest in a completely new system, ultimately saving time and capital.

The Powerware 2500 also features an intuitive graphical user interface, which simplifies system management and monitoring. Users can view real-time status updates, access performance metrics, and configure settings with ease, reducing the burden on IT staff. Additionally, remote management capabilities enable administrators to monitor the UPS from any location, further enhancing operational efficiency.

Moreover, the Powerware 2500 includes comprehensive safety features. It is equipped with automatic battery tests, overload protection, and short-circuit protection to safeguard both the UPS and the connected loads. The advanced battery management system extends battery life by optimizing charging cycles and reducing wear.

Ultimately, the Powerware 2500 stands out as a top-tier UPS solution that marries advanced technology with practical features. Its combination of high efficiency, reliability, scalability, and user-friendly management makes it an ideal choice for organizations requiring a robust power protection solution. With the ability to adapt to changing power needs while ensuring the safety of critical operations, the Powerware 2500 continues to be an essential component in the infrastructure of various industries.