UltraTrak100 TX4 and UltraTrak100 TX8 User Manual

The first line of the Idle mode menu will display one of the following status messages:

Array Functional

The array is fully operational, and no problems are

 

 

present.

Array Critical

The array is operational, but has lost its fault tolerance.

 

 

For RAID array levels 1, 3 and, 5 the array contains a

 

 

failed drive. The user should identify and replace the

 

 

failed drive.

Array Offline

The array is no longer operational. The array must be

 

 

rebuilt from the last tape backup or other device. For

 

 

RAID levels 1, 3, and 5, at least two or more drives in

 

 

the array have failed. For a RAID 0 array, at least one

 

 

drive has failed. The user should identify and replace

 

 

the failed drives.

The second line of the Idle mode menu can also provides the following error information:

Fan Error

Fan speed is <2000RPM or >5500RPM

Array Rebuilding xx% At least one array is rebuilding

Array Synchronizing xx% At least one array doing synchronize

CONFIGURATION MENU

In Configuration mode you may view the status of the UltraTrak100 system and configure both UltraTrak100 hardware and arrays. The main configuration menu allows the user to select the following menus:

 

View Status

 

 

 

 

Configure Array

 

 

 

 

 

 

 

 

 

 

Configure Cache

 

 

Press or to move these items on the LCD.

 

Configure SCSI

 

 

 

 

 

 

What you can do:

 

 

 

 

Press SEL:

Selects one of the following active functions:

 

View Status

 

Moves the display to the View Status menu.

 

Configure Array

Moves the display to the Configure Array menu.

 

Configure Cache

Moves the display to the Configure Cache menu.

 

Configure SCSI

Moves the display to the Configure SCSI menu.

 

Press

:

Moves the active message line up. (Active is marked by *.)

 

 

 

 

 

Press

:

Moves the active message line down. (Active is marked by *.)

 

 

 

 

 

Press EXIT:

Returns to the Idle mode.

20

Page 26
Image 26
Promise Technology TX8, TX4 user manual View Status Configure Array Configure Cache, Configure Scsi