9–Fibre Channel Interactive Commands
Transceiver Diagnostics Monitoring Interface (DMI)
9-36 SN0054667-00 C

General (-dm)

3. Transceiver Diagnostics Monitoring Interface (DMI)<port selection>1. General

From the Transceiver Diagnostics Monitoring Interface menu, select the General

option to view general transceiver diagnostic information. For example:

------------------------------------------------------------------------------
HBA Instance 0: QLE2462 Port 1 WWPN 21-00-00-1B-32-17-F9-C4 PortID 00-00-00
------------------------------------------------------------------------------
------------------------------------------------------------------------------
Media Information
------------------------------------------------------------------------------
Vendor: FINISAR CORP.
Type: 400-M6-SN-I
Part Number: FTLF8524E2KNL
Speed: 100 MBytes/Sec, 200 MBytes/Sec, 400 MBytes/Sec
Revision: A
Serial Number: PBA00CE
------------------------------------------------------------------------------
Temperature Voltage Tx Bias Tx Power Rx Power
(C) (V) (mA) (mW) (mW)
-------------- ------- ------- -------- --------
Value 41.78 3.32 7.43 0.3624 0.0001
Status Normal Normal Normal Normal Fault
High Alarm 95.00 3.90 17.00 0.6310 1.2590
High Warning 90.00 3.70 14.00 0.6310 0.7940
Low Warning -20.00 2.90 2.00 0.0790 0.0158
Low Alarm -25.00 2.70 1.00 0.0670 0.0100