IBM eServer BladeCenter Fibre Channel Switch Module
Timeout Values
QLOGIC SWITCH INTEROPERABILITY GUIDE PAGE 131
VERSION 1.0, MARCH 2003
3. From the Switch Properties— IBM BladeCenter SAN Utility dialog box, verify that R_A_TOV
is set to 10000 and E_D_TOV is set to 2000. If the settings are not correct, proceed to step 4.
If the settings are correct, no changes need to be made; proceed to the next appropriate
section.
4. From the Switch Properties— IBM BladeCenter SAN Utility dialog box Administrative
State list, select offline. Click OK.
5. Re-enter the Switch Properties—IBM BladeCenter SAN Utility dialog box (see step 2). DO
the following:
a. In the R_A_TOV box, enter 10000.
b. In the E_D_TOV box, enter 2000.
c. Click OK.
6. Re-enter the Switch Properties—IBM BladeCenter SAN Utility dialog box (see step 2). In
the Administrative State list, select Online. Click OK.