Quadra-Fire SAPPH-D-CSB, 839-1460 Gas Information, A. Fuel Conversions, Converting to LP Gas

Models: 839-1440 SAPPH-D-CSB 839-1390 SAPPH-D-CWL 839-1460

1 56
Download 56 pages 16.44 Kb
Page 23
Image 23
6 Gas Information

6 Gas Information

A. Fuel Conversions

Before making gas connections ensure that the appliance being installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a quali- fied technician using Hearth & Home Technologies specified and approved parts.

1. Converting to LP Gas

NOTE: Gas conversions should only be performed by a qualified service person, and/or where required by state and local codes, licensed installer/service technician. In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitter.

KIT CONTENTS: Replacement orifice; replacement pilot injector; valve regulator; and conversion label.

TOOLS REQUIRED: Power drill (a 90° handle is help- ful); #2 Phillips bit; 5/32" Allen wrench; 5/8" open end wrench.

IMPORTANT NOTE! The orifice supplied with this con- version kit is for TOP VENT MODELS ONLY. If your stove was fitted with the rear vent kit, the correct conversion orifice was supplied WITH THE REAR VENT KIT.

Figure 6.1 Remove front (if installed), glass, and logs (if installed.) Using the #2 Phillips screwdriver remove the two

(2)1/4" x 20 screws securing the burner as indicated. Lift burner out of firebox.

Figure 6.2 Remove the burner support by loosening the left screw on the pilot tower, and removing the two screws on the front side of the burner neck support.

Figure 6.3 Slide the burner neck support to the left. Pull off pilot hood and set aside.

Figure 6.4 Use a 5/32" Allen wrench to remove the pilot injector.

January 28, 2008