Quadra-Fire 839-1440 1Listing and Code Approvals, A. Appliance Certification, C. BTU Specifications

Models: 839-1440 SAPPH-D-CSB 839-1390 SAPPH-D-CWL 839-1460

1 56
Download 56 pages 16.44 Kb
Page 4
Image 4
1Listing and Code Approvals

1Listing and Code Approvals

A. Appliance Certification

MODEL:

Sapphire

LABORATORY:

OMNI Test Laboratories, Inc.

 

061-S-19b-5

TYPE:

Direct Vent Gas Heater

STANDARD:

ANSI Z21.88a-2000ּCSA 2.33a-M00ּ

 

UL307bּCAN/CBA 2.17-M91

The product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and Recre- ational Vehicles” and "Gas Fired Appliances for use at High Altitudes".

Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.

When installed, the appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

C. BTU Specifications

Model

Maximum

Minimum

Orifice

*Steady

**P.4

Input

Input

Size

State

(US or Canada)

%

 

BTU

BTU

(DMS)

Efficiency %

 

TOP VENT:

 

 

 

 

 

Sapphire (NG)

30,000

21,000

36

84

64

Sapphire (LP)

30,000

24,500

52

82

65

 

REAR VENT:

 

 

 

 

 

Sapphire (NG)

26,000

18,000

41

84

64

Sapphire (LP)

26,000

20,000

53

82

65

 

*Thermal efficiency maximum pipe with blower on.

**Canada minimum pipe.

D. High Altitude Installations

Omni-Test Laboratories listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U.S.A. and 0 to 4500 feet in Canada.

When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities.

B. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

A. Appliance Certification WARNING

Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

E. Non-Combustible Materials

Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, shall be considered non-combustible materials.

F. Combustible Materials

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other materials that can ignite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

Page 4

Quadra-Fire · Sapphire · 250-7233F

January 28, 2008

Page 4
Image 4
Quadra-Fire 839-1440 1Listing and Code Approvals, A. Appliance Certification, C. BTU Specifications, B. Glass Specifications