2.Replace Burner Orifice for Horizontal Vent Configurations

Figure 8.4 Install the inner flue collar on rear of appliance, with damper rod pointing up. A dab of high temperature silicone on the gasket will help gasket adhere to the appliance.

Figure 8.5 Install the inner flue cover on top of the appliance, ensuring that the damper rod is in the up position.

Figure 8.6 Install the outer flue cover, with damper adjustment plate attached, to the top of the appliance.

On top of the appliance: Reattach the damper adjustment with screw.

Figure 8.7 Install the inner collar and outer flue collar on the rear of the appliance.

Install the rear vent cover plate, supplied iwth the kit, on the back shield.

Reinstall the cast insert piece in the top of the appliance.

NOTE: A grill cover plate is shipped with the appliance. This plate may be placed beneath the top grille. The use of the plate increases blower efficiency and also hides the interior of appliance from view. See next page for installation instruc- tions.

2.Replace Burner Orifice for Horizontal Vent Configurations

Remove front, glass, and logs (if installed).

Figure 8.8 To remove the burner pan locators from the left and right sides of the burner, remove one screw from each side, lift locators up and out.