4. Existing Masonry Chimney

Type A - Up & Out Installations for Top Vent Configurations

 

 

 

 

 

 

 

 

TERMINATION

TOP ADAPTOR

 

 

 

 

 

 

 

CAP

 

 

 

 

 

 

 

 

 

 

 

 

 

FLASHING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RETRO

 

 

CONNECTOR

 

4 in. (102mm)

 

90 DEGREE

 

FLEX LINER

 

 

ELBOW

 

 

DIRECT VENT

PIPE

Type B - Hearth Rear Vent Installations for Use With Rear Vent Kit (see Section 12 for conversion kit and venting components.)

Chimney Liner

Termination Cap

Part #923GK

 

Co-Axial to

3 in. (76mm)Flex

 

Co-Linear

Liner

 

Connector

 

 

Part #923GCL

 

Pipe Length

 

Optional

 

 

 

 

 

 

Showing two

 

 

 

 

 

 

 

 

 

 

30 ft. (9m)

 

 

 

 

 

Sections of Flex

 

 

 

 

 

Liner

 

 

 

 

 

 

Chimney Liner

Termination Cap

Co-Axial to Co-Linear

Connector

Pipe Length

Optional

30 ft. (9m) of 3 in. (76mm) Flex Liner Exhaust Section

This section of the chimney MUST be sealed

The chimney must be sealed from the 4 ft. (1m) section to termination

using a smoke shelf or a damper*.

The seal should be 6 in. (152mm) below the end of the 4 ft. (1m) Air Intake section.

4 ft. (1m) of 3 in. (76mm)

Flex Liner

Air Intake Section

Figure 5.23

*In the Commonwealth of Massachusetts, the word damper shall be replaced with the words flue restrictor.

Page 20

Quadra-Fire · Sapphire · 250-7233F

January 28, 2008

Page 20
Image 20
Quadra-Fire 839-1460, SAPPH-D-CWL, 839-1390, SAPPH-D-CSB, 839-1440 owner manual Existing Masonry Chimney, Ft m