R
DV400S DIRECT VENT ROOM HEATER
Firebox Entry
A. Removing the Front Face.
1.Loosen the thumb screw from the bottom of the unit that holds the front face in position. See Figure 16.
2.Carefully lift the front face up and pull the bottom forward. Place it in a safe place.
C. Log Placement.
The logs are shipped in separate packaging. Refer to Fig. 18 for identification, and Fig 19, 20, and 21 for the installation process.
Figure 16 - Bottom Thumb Screw
B. Removing the Glass.
3.Remove the glass frame assembly by pulling the latch releas- es forward and upward. See Figure 17. Lift the glass frame assembly up, sliding the [3] tabs at the bottom out of the slots.
Figure 17 - Removal of Sealed Glass
1.
3. | 1. Rear Log | |
2. Front Log | ||
| ||
| 3. Top Log |
2.
Figure 18 - Log Identification
Fig. 19
Rear Log
Placement
Fig. 20
Front Log
Placement
Fig. 21
Top Log
Placement
D.Creating the Coal Bed Look. Ember Chunks.
Randomly place the ember chunks on the burner tube between and in line with the two front logs, creating a small wall of embers. Do not allow the chunks to cover the burner ports or air holes in the burner tube as this may restrict air and/or gas flow, creating a less than satisfac- tory performance. Too much restriction can cause improp- er combustion and sooting (especially with an appliance using propane gas).
Mineral wool may be bridged over the chunks for greater enhancement.