E. Adjustable Flue Restrictor

R

DV400S DIRECT VENT ROOM HEATER

E. Adjustable Flue Restrictor

The DV400S has an adjustable flue restrictor for maximum performance for vertical installations. The unit is shipped with the restrictor in the open position and should be left open with any horizontal installation.

To access the adjustable flue restrictor bolt you must take the following steps:

1. Remove the front face of the unit.

 

2. Remove the glass and set in a safe

 

place.

 

The adjustable bolt can be accessed by reaching through the

Figure 23- Decorative Door Trim

firebox to the back of the unit. See Figure 22.

 

The amount to close the restrictor will depend on the vent height. If the vertical height is 20 feet or more, the restrictor can be closed all the way. Anything less will require some setting less than closed. The setting will vary depending on the installation.

Any offsets in a vertical installation will restrict the system and the flue restrictor will not need to be closed as much.

The screws are thread cutters and a power screwdriver is neces- sary to drive the screws into position. See Figure 23.

I. Replacing the Front Face

Carefully lift the front face into position and replace the thumb screw to hold it in position.

Figure 22 - Adjustable Flue Restrictor

F. Clean the Glass

To clean the glass, use a non-abrasive, mild cleaning solution. (For example, a glass cleaner or for stubborn film, an oven cleaner.) Apply an adequate amount to the glass and wipe off with a damp cloth. Be sure all cleaner is thoroughly rinsed from the glass.

G. Install the Glass

After cleaning the glass, carefully place the Glass Frame Assembly onto the unit by positioning the tabs at the bottom of the frame into the slots. Pull the latch releases forward and hook over the glass frame.

H. Optional Door Trim Kit Installation

The decorative trim can be installed at this time.

1.Lay the front face on a flat surface being careful not to damage it.

2.Remove the lower shield by removing the (3) screws.

3.Lay the door trim onto the front face and put the shield back in position and attach with the screws provided and those removed earlier.

WARNING!

NEVER OPERATE THIS APPLIANCE WITH THE DOOR AND/OR GLASS REMOVED OR NOT SEALED.

WARNING!

DO NOT OPERATE APPLIANCE WITH THE PANEL(S) REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.

Pre-Use Check List

Before operating this heater, please review the safety precau- tions given on page 4 as well as the items listed below:

1.Check to make sure the logs are securely in place and the rock wool, and Ember Chunks have all been placed correctly. (Refer to Page 23.)

2.Check to see that all wiring is correct and enclosed to prevent possible shock.

3.Check to ensure there are no gas leaks. This may be done with a soap and water solution.

4.Make sure the glass is sealed and in its proper position. Never operate this heater with the face removed or glass removed or not sealed.

5.Verify that all venting and caps are unobstructed. Exhaust gases are extremely hot. Check for obstructions from trees, bushes, snow drifts, etc.

6.Read and understand these Instructions thoroughly before attempting to operate this heater.