Quadra-Fire Clearances, DV400S DIRECT VENT ROOM HEATER, Dura-Ventgs, Venting System Components

Models: DV400S

1 32
Download 32 pages 16.84 Kb
Page 8
Image 8
DURA-VENT GS

 

R

 

DV400S DIRECT VENT ROOM HEATER

 

 

 

 

 

 

 

 

 

DURA-VENT GS

VENTING SYSTEM COMPONENTS

 

CATALOG #

DESCRIPTION

 

 

 

 

953

Storm Collar

 

963

Firestop Spacer

 

988

Wall Strap

 

981

Snorkel Termination (36")

 

982

Snorkel Termination (14")

 

971

Horizontal Kit (Horizontal Termination Cap, One 90 Degree Black Elbow, Wall

 

 

Thimble, 24" Black Pipe, 11" - 14 5/8" Adjustable Vent

 

980

Vertical Termination Cap with Wind Halo

 

984

Horizontal Termination Cap

 

909B

Retrofit Adjustable Chimney Connector Retrofit Chimney Connector Plate

 

950

VSS - Vinyl Siding Standoff/Shield

 

3951

Round Ceiling Support/Wall Thimble Trim Kit, Polished Brass

 

3960

Cathedral Ceiling Support Trim Kit, Polished Brass

 

HHW2

Horizontal High Wind Cap (recommended for optimal performance)

 

HHW2K

Horizontal Kit (One 90 degree Elbow, Wall Thimble, 24" Black Pipe, 11" - 14 5/8"

 

 

Adjustable Vent, HHW2 Termination Cap.

 

 

 

 

CLEARANCES

The following clearances to combustibles must be main- tained:

Minimum clearances to the floor - 0"

Back of unit to wall - 6”

Sides of unit to wall - 6

Base of the unit to ceiling - 72".

Minimum clearances to Venting are as follows:

Horizontal runs require a 1-1/2” minimum Air Space on the top and an 1/2” minimum Air Space on the sides and bottom of the outer Vent Section. If an Elbow is being used,in an enclosed wall, floor or ceiling, a top Air Space clearance of 3” must be maintained. Vertical rise sections require a 1” minimum Air Space completely around the Vent section. These clearances must be maintained at all times.

This appliance is certified for installation in a bed/sitting room in the U.S. and Canada.

Mobile Home Installations. Appliances installed in Mobile Homes must be secured to the floor in a minimum of two locations.

Positioning the Appliance.

This appliance may be placed on a combustible or non-combus- tible continuous, flat surface. When the appliance is installed directly on carpeting, tile or other combustible material other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. Slide the Heater into position and level the Heater from side-to-side and front-to-back. Shim as necessary.

Figure 1

Minimum Clearances To Combustibles

6"

4"

 

 

6"

 

STOVE

4"

 

 

 

6"

 

 

6"

48"

 

STOVE

 

MAX.

 

HEARTH PROTECTION IS NOT

 

NECESSARY ON THIS GAS HEATER.

March 4, 2002

Page 8

30211C