7.7 Termination Resistors

Optional line termination resistors are provided for the input signals of each of the DS-200/300’s RS-422/485 ports. The user has the option of selecting RS-422 termination (￿￿￿￿), RS-485 termination (120￿), or no termination. Line termination may be selected or removed using jumper block J1. The board is shipped with no termination selected.

SIGNAL

CHANNEL

TERM SIZE

PINS

 

 

 

JUMPERED ON

 

 

 

J1

RXD

Serial 0

100￿

1-9

 

 

120￿

2-10

AUXIN

Serial 0

100￿

3-11

 

 

120￿

4-12

RXD

Serial 1

100￿

5-13

 

 

120￿

6-14

AUXIN

Serial 1

100￿

7-15

 

 

120￿

8-16

Figure 24 --- RS-422/485 Line Termination

J1

8

7

6

5

4

3

2

1

 

16

15

14

13

12

11

10

9

Figure 25 --- Line Termination Option Block

7.8 RS-422/485 Peripheral Connection

The DS-200/300 connects to peripheral equipment through two female D-9 connectors. The serial port connector definitions are listed in Figure 28.