2. Installation
If the default address and interrupt settings are sufficient, the DS-200/300 can be quickly installed and put to use. The factory defaults are listed in Figure 1.
PORT | ADDRESS | IRQ | ENABLED |
| | | |
Serial 0 | 3F8 hex | 4 | YES |
| | | |
Serial 1 | 2F8 hex | 3 | YES |
| | | |
Figure 1 --- Default address and IRQ settings for DS-200/300
The output of the DS-200/300 is two 9-pin D-connectors labeled CN1 (serial 0) and CN2 (serial 1).
1.If the default settings are correct, skip to step 2, otherwise refer to sections 4 and 6 of this document for detailed information on how to set the address and IRQ level.
2.Turn off the power of the computer system in which the DS-200/300 is to be installed.
3.Remove the system cover according to the instructions provided by the computer manufacturer.
4.Install the DS-200/300 in any vacant expansion slot. The board should be secured by installing the Option Retaining Bracket (ORB) screw.
5.Replace the system cover according to the instructions provided by the computer manufacturer.
6.Attach and secure the cable connectors to the desired equipment.
DS-200/300 User's Manual | 2-1 |