Rangemaster 110 Technical Data, This cooker is designed for use on either, Dimensions, Ratings

Models: 110

1 32
Download 32 pages 37.07 Kb
Page 30
Image 30
Technical Data

Technical Data

This cooker is designed for use on either :-

NATURAL GAS (Cat I2H ) at 20mbar or

LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.

NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.

INSTALLER: Please leave these instructions with the User.

DATA BADGE LOCATION:

Cooker back, serial number repeater badge below oven door opening.

Country of Destination: GB/IE

 

Dimensions

Overall height

minimum

893mm

maximum 920mm

Overall width

 

1100mm

See ‘Positioning of Cooker’

Overall depth

 

648mm

 

Space for fixing

 

See ‘Positioning of Cooker’

Minimum space above hotplate

650mm

 

Connections

Gas:

Electric

Rp 1/2 at rear right-hand side

230V 50Hz

Ratings

 

Natural Gas

L.P. Gas

 

 

 

Injector

 

Injector

Hotplate

 

 

 

 

Large Burner

3.0kW

134

3.0kW (210g/h)

87

Medium Burners

1.7kW

109

1.7kW (119g/h)

68

Small Burner

1.0kW

75

1.0kW (70g/h)

51

Oven

3.2kW

237

2.9kW (224g/h)

85

Grill

2.73kW

190

2.73kW (192g/h)

85

Gas burner inputs based on Gross Calorific Value

 

 

 

 

 

 

 

Griddle

1.5kW

 

1.5kW

 

Warmer

160W

 

160W

 

Maximum total electrical load at 230V 1.8kW (approximate total including oven lights, etc.)

30

Page 30
Image 30