INSTALLATION
OPTIONAL REMOTE
CONTROL
Use the Optional Remote Control Kit approved for this unit. Use of other systems may void your warranty.
The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.
1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very impor- tant). Run wires from the fireplace to that location. Use Thermostat Wire Table.
2)Connect the two wires to the gas valve.
3)Install a 9V alkaline battery in both receiver and the transmitter. Install the receiver and
cover in the wall. The remote control is now ready for operation.
CAUTION
Do not connect the millivolt
remote control wires to
the 240V wires.
OPTIONAL WALL
THERMOSTAT
A wall thermostat may be installed if desired. Use chart below to determine thermostat wire length.
Note: Preferable if the thermostat is in- stalled on an interior wall.
Use a CSA, UCL or UL approved millivolt thermo- stat,
CAUTION
Do not connect the millivolt
wall thermostat wires
to the 240 V wires.
Thermostat Wire Table
Recommended Maximum Lead Length
Thermostat
Wire Size | Max. Length |
14 GA. | 15.24 m |
16 GA. | 9.75 m |
18 GA. | 6.10 m |
20 GA. | 3.66 m |
22 GA. | 2.71 m |
No electrical power supply is required for the gas control to operate. However, a 240V A.C. power supply is needed for the fan/blower operation.
Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
WIRING
WARNING: Electrical Grounding Instructions This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded
CAUTION:
Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Regency | 15 |