INSTALLATION

MINIMUM FIREPLACE

DIMENSIONS

The minimum fireplace dimensions for the Re- gency gas space heater are shown in the following diagrams:

GAS CONNECTION

GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the neces- sary gas connections to this appli- ance.

1)If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace.

2)The gas connection is 12" BSP.

Mantel Clearances with Bay and Flush Louvres in Masonry Installation

MINIMUM

CLEARANCES TO COMBUSTIBLES

The minimum fireplace clearances for the Re- gency gas space heater are shown in the following diagrams:

 

From Unit

 

Sides

A

255 mm

Ceiling

B

1205 mm

Mantle

C

see Mantel

 

 

Clearances

From Surround (660 mm x 1016 mm)

Max. Mantle Depth

G

305 mm

Hearth Height

H

0 mm

Hearth Depth

I

405 mm

Hearth Width

J

1015 mm

Min. Alcove Width

K

1220 mm

Max. Alcove Depth

L

915 mm

NOTE: Mantel clearances for Installation into a Zero Clearance Kit are differ- ent. Please refer to the Zero Clear- ance Kit Manual for details.

Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non-combustible board.

3)Locate the center point where the flue will pass through the chimney above the appli- ance. Move the appliance into the exact location where it is to be installed. Ensure that the Insert is level.

4)The installer must provide a valve with a plugged tapping, accessible for test gauge connection, immediately upstream of the gas supply connection to the appliance.

CAUTION: If the glass is removed or opened for servicing, it must be re- placed and closed prior to operating the appliance. The glass must be fixed in the door when operating.

SPECIFICATIONS

 

NG

LPG

 

 

 

INJECTOR

#37

#52

SIZE

2.65mm

1.6mm

 

 

 

INPUT

Min. 17 mj/h

Min. 17 mj/h

RATING

Max. 31 mj/h

Max. 31 mj/h

MANIFOLD

 

 

PRESSURE

Max. 0.9 kPa

Max. 2.59 kPa

 

 

 

6

Regency I31-3 Gas Fireplace Inbuilt

Page 6
Image 6
Regency I31-NG3, I31-LPG3 Minimum Fireplace Dimensions, GAS Connection, Minimum Clearances to Combustibles