MAINTENANCE
GLASS GASKET | 7) | screws on each side of the tray. Push the |
| Remove the Burner Tray by removing the |
If the glass gasket requires replacement use 7/8" flat glass gasket (Part #
tray to the left and lift up.
FAN MAINTENANCE
If your fan requires maintenance or replace- ment, access to the fan is through the plate on the rear wall of the firebox. NOTE: the unit
MUST NOT be operated without the fan access panel securely in place.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring error can cause improper and dangerous opera- tion.
To remove fan:
1)Turn the unit off and allow it to cool to room temperature.
2)Unplug or disconnect power source to stove.
3)Remove glass front (see page 10).
4)Remove logs.
5)Remove brick panels.
6)Remove the Grate by removing the screws on each side of the grate.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
8)Remove the 11 screws holding the Access Panel in place.
9)Remove the Fan Air Duct by removing 4 screws, 2 per side.
10)Unplug the black wires from the fan motor (from inside the stove).
11)Lift Fan Assembly off of the 2 pins, tip forward and pull through firebox opening.
12)Disconnect green wire from power cord.
Replacing fan:
Reverse above steps. Hint for pushing fan down onto pins - rub a bit of dish soap on the grommet so it will slide more easily onto the pin. Check to make sure the fan is seated properly on the pins, this is very important- try to move the fan back and forth, there should be no noise, if there is check that the grommets haven't come loose.
Remove the 2 screws holding the
grate in position.
Regency | 19 |