MAINTENANCE

VALVE ASSEMBLY REPLACEMENT

1)Unplug or disconnect the power source to the stove and shut off gas supply.

2)open bottom louvre and remove protective screen.

3)Remove the door frame and safety screen.

4)Remove the glass door, logs, and black or stainless inner liner, if installed.

5)Remove the rear log tray, burner and grate.

6)Disconnect gas line from the valve.

7)Remove the firebox base plate by removing the 10 screws which hold it in place.

8)Remove all the wire connectors from the valve and spark ignitor.

9)Remove the valve tray assembly.

10)To replace the valve tray assembly, simply reverse the above steps.