INSTALLATION

INSTALLATION IN MASONRY OR ZERO CLEARANCE CHIMNEY

1)Measure and record dimensions to determine total Flex Liner length requirements (see instructions below for details).

2)Carefully feed the liner down the chimney (masonry or zero clearance) and out through the damper. One person should feed the liner through the chimney, and another person should pull the liner from the bottom.

3)After carefully feeding the Flex Liner down the chim- ney to the bottom, form and angle to line up the Flex Liner with the vent opening on the appliance. Important: Do not let the Flex Liner sag below the level at which it will connect to the appliance or connector. This could allow hot gas to become trapped and poten- tially become a fire hazard. The Flex Liner path should always be sloped up toward the Termination Cap.

4)Temporarily secure the Flex Liner at the top of the chimney. Be sure to leave 2-3 inches of flex above the existing chimney to allow for connection to the Termina- tion Kit (Baseplate and Adaptor).

Flex

Liners

Existing

Chimney

Note: If you are planning to extend the height of the chimney using Direct Vent GS Pipe, please refer to the Direct Vent Installation Instructions for information con- cerning the proper procedure and restrictions of Direct Vent Pipe.

Also, consult the appliance manufacturer for any height restrictions of the chimney.

9) Connect the Co-Linear Flex to the two outlets on the top of the appliance using four sheet metal screws each. See the appliance manufacturer's instructions for de- tails. Make sure the Flex Liners do not sag behind the appliance. Finally, move the appliance into its appropri- ate place. Mount the Adaptor to the Baseplate using sheet metal screws.

5)Repeat Steps 1-4 for second length of Flex Liner.

6)At the top of the chimney, slide the Baseplate over the tow ends of the Flex Liner and secure it to the sur- rounding masonry using masonry anchor bolts. Before installing the baseplate, run a bead of non-hardening seal and between the Baseplate and the masonry to prevent moisture from entering the chimney.

Note: Verify that there is sufficient room to mount the Baseplate on to the masonry. You must have a level surface in order to install the Baseplate properly.

7)Attach the Flex Liner ends at the top of the chimney to the Co-Linear to Co-Axial Adaptor. Use four sheet metal screws to connect each Flex Liner run to the Adaptor.

8)Twist lock the Vertical Termination Cap to the Adap-