Regency IG34-LPG, IG34-ULPG, IG34-NG installation manual Installation

Models: IG34-LPG IG34-NG IG34-ULPG

1 32
Download 32 pages 29.38 Kb
Page 5
Image 5

INSTALLATION

IMPORTANT MESSAGE

The Regency Gas Inbuilt must be installed in accordance with these instructions. Carefully read all the instructions in this manual first.

Note: Failure to follow these instructions could cause a malfunction of the heater which could result in death, serious bodily injury, and/or prop- erty damage. Failure to follow these instructions may also void your fire insurance and/or warranty.

FOR YOUR SAFETY

This appliance requires air for proper combus- tion. Always provide adequate combustion and ventilation air. Follow instructions and information in the current AS5601, NZS 5262 or local codes. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation.

MATERIALS REQUIRED

A 240 Volt AC power cord is hooked up to the unit. Plug 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances.

When connected with 240 volts, the appliance must be electrically grounded in accordance with local codes.

This unit is polarity sensitive and will not operate if polarity is incorrect.

BEFORE YOU START

Installation is to be carried out ONLY by an authorised person.

1)The appliance shall be installed in accord- ance with the manufacturer's installation instructions, local gas fitting regulations, municipal building codes, water supply regulations, electrical wiring regulations, with AS5601. (AGA gas installation code) NZS 5262(New Zealand)

2)Installation and repair should be done ONLY by an authorised person.

3)The appliance should be inspected before use and at least annually by an authorised service person. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean and free from excessive lint from carpeting.

4)See general construction and assembly instructions. This appliance may only be in- stalled in a flued, non-combustible fireplace. The appliance and flue should be enclosed when installed or passing through a living area, where children may come in contact with it.

5)Always connect this space heater to a chim- ney and flue to the outside of the building envelope. Never flue to another room. Make sure that the flue is properly sized and is of adequate height to provide the proper draft.

6)Inspect the flueing system annually for blockage and any signs of deterioration.

7)Any safety glass removed for servicing must be replaced prior to operating the ap- pliance.

INSTALLATION

CHECKLIST

Before installing vent system ensure that the damper plate is open and secure to prevent the damper plate from falling down and crushing the liner.

The FPI Gas Inbuilt is installed as listed.

1)

Check all clearances to combustibles, (Refer

 

to sections "Minimum Fireplace Dimensions

 

and Clearances to Combustibles)

2)

Make the gas connection. (Refer to section

 

"Gas Connection")

3)

Install the 3" (76.2mm) flue liner to the sliding

 

connector plate. (Refer to section "Flue Liner

 

Installation.")

4)

Slide the unit half way into the fireplace.

5)

Pull the vent connector plate through the

 

tapered brackets and fasten to the front plate.

 

Refer to section "Flue Liner Installation.")

6)

Slide the unit fully into the fireplace.

7)

Test gas pressure (Refer to section "Gas

 

Pipe Pressure Testing"). Check aeration

 

system (Refer to section "Gas InsertAeration

 

System").

8)

Install standard and optional features. Refer

 

to the following sections:

 

a. Log Set

 

b. Faceplate & Door Trim

 

c. Inner Stainless Panels

9)

Final check: Before leaving this unit with the

 

customer, the installer must ensure that the

 

appliance is firing correctly. This includes:

 

a) Clocking the appliance to ensure the

 

correct firing rate.

WARNING:

Suitable for installation into a masonry fireplace only.

8)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fireplace.

9)Installer must mechanically attach the sup- plied label to the inside of the firebox of the fireplace into which the gas fireplace insert is installed.

"WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction."

b) Adjusting the primary air and restrictor

settings, if required, to ensure that the

flame does not carbon.

NOTE:

TO BE INSTALLED ON A

NON- COMBUSTIBLE FLOOR.

Regency IG34 Gas Inbuilt Fireplace

5

Page 5
Image 5
Regency IG34-LPG, IG34-ULPG, IG34-NG installation manual Installation

IG34-LPG, IG34-NG, IG34-ULPG specifications

The Regency IG34 series comprises three innovative models: IG34-ULPG, IG34-NG, and IG34-LPG, designed to efficiently meet the demands of modern heating solutions. These gas fireplaces are distinguished by their commitment to energy efficiency, stunning aesthetics, and robust technology.

The IG34-ULPG model is tailored for users who prefer ultra-liquid propane gas options. This model stands out with its exceptional energy efficiency, capable of heating a significant area while minimizing environmental impact. Its sleek contemporary design features a large viewing window, allowing users to enjoy the beauty of the flames while providing warmth. With the advanced remote control technology, users can conveniently adjust settings from anywhere in the room.

On the other hand, the IG34-NG variant is optimized for natural gas users, offering similar efficiency and aesthetic advantages. It also boasts an impressive BTU output, ensuring that spaces remain cozy and inviting during cooler months. The user-friendly interface makes it easy to monitor and regulate the heat output, enhancing both comfort and convenience. One of the hallmark features of the IG34-NG is its state-of-the-art safety mechanisms, including an automatic shut-off system that ensures peace of mind when the unit is not in use.

The IG34-LPG model further extends the versatility of the series by being adaptable to both liquid propane and natural gas. This model is particularly popular among users who desire flexibility, as it can easily be converted from one fuel type to another with minimal effort. Additionally, the IG34-LPG incorporates modern combustion technologies that significantly reduce emissions, making it an environmentally friendly option without compromising performance.

Across the entire IG34 series, the fireplaces are engineered with premium materials ensuring durability and reliability. The direct vent system is a standout feature, allowing for efficient ventilation that minimizes heat loss while maintaining indoor air quality. Each model is equipped with a ceramic glass door that provides excellent thermal efficiency, ensuring that users enjoy maximum warmth without excessive energy expenditure.

In summary, the Regency IG34 series—IG34-ULPG, IG34-NG, and IG34-LPG—offers a compelling blend of efficiency, safety, and modern design. These fireplaces are not just heating solutions; they are lifestyle enhancements that provide comfort and elegance to any living space, making them a smart choice for homeowners seeking stylish and effective heating options.