INSTALLATION

18)Turn on gas supply and plug in power cord.

19)Adjusting the Outlet Pressure

All the adjustments must be carried out in the following order:

Remove the modulator plastic cap (A) using needle nose pliers.

Maximum pressure: Turn the unit ON to its highest input rating. Screw in the nut (B) to increase the outlet pressure and screw it out to decrease it. Use a 10 mm wrench.

NOTE: The outlet pressure must be set to maximum 2.51 kPa.

Minimum pressure: Remove one of the cables connect- ed to the electric modulator. While holding the nut (B) with a wrench, screw in the screw (C) to increase the pressure and screw it out to decrease it. Use a screwdriver 6 x 1 blade.

NOTE: The outlet pressure must be set to minimum 1.6 kPa.

Cable

Electric

Modulator

After carrying out all adjustments, block the setting screws with paint, taking care not to obstruct the breather orifice of the pressure.

Put back the modulator plastic cap.

WARNING: To ensure the correct operation of the modu- lator it is necessary that the plastic cap (A) is returned to its original location.

A

B C

20)Turn on gas supply and plug in power cord.

21)At the end of all setting and adjustment operations, check electrical installation and gas leaks.

22)Check operation of flame control.

23)Check for proper flame appearance and glow on logs.

Installer Notice:

These instructions must be left with the appliance.