FRAMING AND FINISHING

INSTALLATION

FRAMING AND FINISHING

1)For ease of installation, frame your fi replace after it is positioned and the vent system is installed. Remember to install the top standoffs. See the "Unit Assembly Prior to Installation" section. Use 2x4's and frame to local building codes.

CAUTION: Verify your fireplace dimensions, framing methods and finished wall facing details before framing. Determine the total thickness of facing material - drywall plus ceramic tiles, slate, etc. Allow the finish surface to be flush with the front or side of the unit. Total facing thickness can vary from 1/2" (13mm) to 1-1/4" (32mm) thick.

2)When locating your appliance on an exterior wall or in a chase, apply a vapour barrier and drywall, as per local building codes. DO NOT

INSULATE THE FIREPLACE ITSELF.

CAUTION: The unit does not have to be completely enclosed in a chase. The clearance on top of the unit is 0" to the standoffs so combustible building materials can be laid directly on top of the standoffs. You must maintain clearance from the vent to combustible materials for both rigid and flex, see Vent Clearances in the "Clearances" section.

Framing Dimensions

 

P121-2 (See Thru)

P131-2 (Pier)

P121LC-2 / P121RC-2

 

 

 

(Corner Unit)

A

25"(635mm)

25"(635mm)

26-13/16"

 

minus two times

minus two times

minus one time

 

the fi nishing

the fi nishing

the fi nishing

 

material thickness*

material thickness*

material thickness*

B

42-1/2"(1080mm)

42-1/2"(1080mm)

42-1/2"(1080mm)

C

46-3/4"(1187mm)

45" (1143mm)

45"(1143mm)

 

 

minus one time

minus one time

 

 

the fi nishing

the fi nishing

* Finish material thickness includes: drywall, ceramic tile, slate, etc.

P121-2 - See Thru

P121LC-2 - Corner Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P131-2 - Pier
P121RC-2 - Corner Unit

C

A

B

Note: These units are

non-load bearing.

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

11