MAINTENANCE
INSTALLING VALVE
1)Attach the valve to the valve bracket with the 6 (m5x8 metric) screws provided.
2)Reconnect the "gas out" fl are fi tting with an 11/16" wrench.
3)Reconnect the "gas out" fl are nut with a 13/16" wrench.
4)Install piezo ignitor push button assembly and reconnect wire.
5)Reconnect the quick drop out thermocouple nut with a 9mm wrench.
6)Reconnect the pilot tube nut with a 7/16" wrench.
7) Scrape off the old gasket from the floor of the
fi rebox and from the valve tray assembly.
8)Install a new gasket and reinstall the valve tray assembly.
Note: Failure to install a new gasket may severely affect the appliance performance.
9)Reinstall the 16 hold down screws.
10)Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve.
11)Reinstall the Burner Assembly.
FAN REPLACEMENT
1)Shut off power.
2)Remove top louvers.
3)Unplug power wires.
4)Remove 4 screws securing fan to mounting bracket.
5)Remove 2 connector wires.
6)Replace fan.
7)Repeat for opposite side/corner.
8)Reverse steps 1 - 5 for installation.
9)To remove the thermodisc, located at the back center of the unit, slide the thermodisc/cover assembly away from the bracket clip on the undersideofthefirebox.Reverseforinstallation. Ensure that no wires will touch hot surfaces.
13)Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector. (Do not use open fl ame for leak testing.)
14)Fire up the unit temporarily
15)Check the manifold pressure.
16)Reinstall the logs, grate and brick panels as needed.
17)Reinstall the glass doors.
18)Fire up the unit again and check for proper fl ame appearance.
Connector wires
38 | Regency® |