Regency P131, P121RC, P121LC Propane & Natural Gas, Straight Up Vertical Venting, Option

Models: P121LC P121 P121RC P131

1 48
Download 48 pages 21.81 Kb
Page 19
Image 19
(Propane & Natural Gas)

INSTALLATION

RIGID PIPE VENTING ARRANGEMENTS - VERTICAL TERMINATIONS

(Propane & Natural Gas)

Vent must be supported at offsets

Maintain clearances to combustibles as listed in the "Clearances" section.

Firestops are required at each floor level and whenever passing through a wall.

Must use optional rigid pipe adaptor when using rigid pipe vent systems (Part# 510-994).

The P121-2/P121LC-2/P121RC-2/P131-2 is approved for a maximum 35 ft. (10.7m) straight vertical, with rigid pipe vent systems for Propane and Natural Gas, as per diagram 7 below.

Straight Up Vertical Venting

Vertical Venting with One (1) 90o Elbow

 

 

 

 

 

Option

V

H

 

A)

1' (305mm) Minimum

2' (610mm) Maximum

 

B)

2' (610mm) Minimum

4' (1.22m) Maximum

 

C)

3' (914mm) Minimum

6' (1.86m) Maximum

 

D)

4' (1.22m) Minimum

8' (2.4m) Maximum

 

 

 

With the above options, maximum total pipe length if 37 feet

 

with minimum of 4 feet total vertical and maximum 8 feet total

 

horizontal.

 

 

 

Please note minimum 1 foot between 90o elbows is required.

Diagram 7

Diagram 8

IMPORTANT

When installing this unit vertically, the 45o elbow when installed in conjunction with the Rigid Pipe Adaptor will pertrude past the unit 1-1/2" (38mm) when measured from the rear standoffs.

Note: A 1-1/4" (32mm) clearance from the elbow must also be maintained.

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

19

Page 19
Image 19
Regency P131, P121 Propane & Natural Gas, Straight Up Vertical Venting, Vertical Venting with One 1 90o Elbow, Option