Regency P121LC Installer Notice These instructions must be left, with the appliance, Heat Shield

Models: P121LC P121 P121RC P131

1 48
Download 48 pages 21.81 Kb
Page 26
Image 26
Ground

INSTALLATION

25)Locate the ground lug at the receptical box, left of the unit.

26)Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit.

Ground

wire from

kit

29) Plug the DC spark generator wires to the

33) Find a location which is not too hot and is

DC Sparker.

easy to reach for changing the

 

battery.

 

34) Tie up the loose wire with the wire clip.

30)Connect the ground wire to the DC Sparker mounting bracket.

35) Check for gas leaks.

36) Check inlet and outlet pressures.

37) Check operation of fl ame control.

38) Check for proper fl ame appearance and glow on logs.

27)Install the 1/2" bushing to the heat shield.

31) InstallthesuppliedbatteryintotheDCSparker Box by opening the battery compartment.

NOTE: The battery in the DC Sparker Box will need to be replaced annually.

Installer Notice:

These instructions must be left

with the appliance.

28)Run the other end of the ground wire and DC spark generator wires through the bushing on the heat shield.

Heat Shield

Battery

Compartment

32)Mount the heat shield to the DC Sparker. Secure into place with the velcro, which is provided in the kit.

26

Regency® P121-2/P121LC-2/P121RC-2/P131-2 Zero Clearance Direct Vent Gas Fireplace

Page 26
Image 26
Regency P121LC Installer Notice These instructions must be left, with the appliance, Ground wire from kit, Heat Shield