Regency U37-NG1, U37-LP1 Installation, Rigid Pipe Venting - Vertical Terminations

Models: U37-LP1 U37-NG1

1 36
Download 36 pages 8.33 Kb
Page 11
Image 11
RIGID PIPE VENTING - VERTICAL TERMINATIONS

INSTALLATION

RIGID PIPE VENTING - VERTICAL TERMINATIONS

FOR BOTH RESIDENTIAL & MANUFACTURED HOMES/MOBILE HOMES

Vertical Terminations

Vertical Terminations

with Co-linear Flex System

using Rigid Piping Systems

The shaded area in the diagram shows the allowable vertical terminations installed in a masonry chimney.All vertical vent instal- lations require the Vent Restrictor to be set to 1-1/4" (32mm) open.

Straight Vertical Terminations

The shaded areas in the two diagrams below show all allowable combinations of straight vertical and offset to vertical runs with vertical terminations. Maximum one 90o elbow. All vertical and offset to vertical vent installations require Vent Restrictor to be set to 1-1/4" (32mm) open. If the vent is ENCLOSED in a chase (min. size 9" x 9") maintain a 1-1/4" (32mm) clearance to combustibles.

Offset to Vertical Terminations

If using a Rigid Pipe Venting Sys- tem a rigid pipe adaptor #640-994 is required.

Rigid Pipe

Adapter

WARNING:

Do not combine venting components from different venting systems.

However use of the the AstroCapTM and FPI

Riser is acceptable with all systems.

This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with Duravent Direct-Vent GS, Selkirk Direct-Temp, Ameri Vent Direct venting and Security Secure Vent systems. Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components.

When using Rigid Vent other than

Simpson Dura-Vent, 3 screws must be used to secure rigid pipe to adaptor.

The FPI AstroCapTM and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent®Direct Vent GS, American Metal Products Ameri Vent Direct Vent, Security Secure Vent®, Selkirk Direct-Temp. Astro- CapTM is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct VentGSareregisteredand/orproprietarytrademarks of Simpson Dura-Vent Co. Inc.

Vent Restrictor Position

Vent restriction is required for certain venting installations, see the diagrams in "Venting Arrangment" section to deter- mine if they are required for your installation.

To set the Vent restriction as indicated in the diagram, simply loosen the screws and push the ventrestrictorplatetothecorrect position. Tighten the screws.

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

11

Page 11
Image 11
Regency U37-NG1, U37-LP1 Installation, Rigid Pipe Venting - Vertical Terminations, with Co-linearFlex System