INSTALLATION
INSTALLATION
CHECKLIST
1)Locate your appliance. Refer to the following sections:
a.Clearances to Combustibles
b.Locating your Ultimate Gas Stove
c."Venting" to "Rigid Pipe Venting - Vertical Terminations" sections.
2)Install venting. See "Planning Your Venting Installation" to "Vertical Termination with
3)Make gas connections. Refer to the "Gas Connection" section.
Test the pilot. Must be as per diagram in the "Maintenance Instructions" section.
4)If necessary, convert from Natural Gas to Propane. Refer to the "Conversion Kit from NG to LPG" section.
5)Installl standard and optional features. Refer to the following sections where applicable:
a.Log Set Installation
b.Door Installation
c.Louver Installation
d.Wall Thermostat
e.Remote Control
6)Final check. Refer to the "Final Check" sec- tion.
Before leaving this unit with the customer, the installer must ensure that the appliance is fi r- ing correctly and operation fully explained
to customer.
This includes:
1)Clocking the appliance to ensure the correct fi ring rate (rate noted on label) after burning appliance for 15 minutes.
2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for
CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1)Ensure that structural members are not cut or weakened during installation.
2)Ensure proper grounding using the #8 ground lug provided.
3)Appliance must be anchored to the fl oor with the supplied anchoring methods.
CLEARANCES TO
COMBUSTIBLES
The clearances listed are MINIMUM distances. Measure the clearance to both the appliance and the chimney connector. The farthest distance is correct if the two clearances do not coincide. For example, if the appliance is set as indicated in one of the diagrams but the connector is too close, move the stove until the correct clearance to the connector is obtained.
This appliance may be installed only with the clearances as shown in the situations pictured.
Do not combine clearances from one type of installation with another in order to achieve closer clearances.
This unit can be installed on a solid combustible surface like a wood fl oor. This unit can also be installed directly on carpeting or vinyl when the bottom pedestal cover plate (provided with unit ) is installed.
Use the minimum clearances shown in the dia- grams below:
Clearances |
|
A Side Wall to Unit | |
B Back Wall to Unit | 3" / 76 mm |
E Side Wall to Unit | |
| |
Reference Dimensions | |
C Floor to Flue Centerline | 25" / 635 mm |
D SideWall to Flue
Minimumceilingheight
is 36" / 914 mm from
top of unit.
LOCATING YOUR
GAS STOVE
When selecting a location for your stove, ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation.
For Vent Termination requirements, see the "Exterior Vent Terminal Locations" section.
This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.
This appliance is Listed for Alcove installations, maintain minimumAlcove clearances as follows, minimum ceiling height of 66"(1.7m), minimum width of 41"(1.0m) and a maximum depth of 36"(0.9m).
A) Cross Corner
B)Flush with Wall/Alcove
C) Flat on Wall Corner
D)Flat on Wall
COMBUSTION AND VENTILATION AIR
The combustion air from this appliance is drawn from outside the building through the outer fl ue.
Extra provision for combustion air inside the room is not required.
VENTING
The Regency® Direct Vent System (Horizontal Termination Kit
The Horiz. Termination Kit
7 |