INSTALLATION

GAS CONNECTION

The gas connection is a 3/8" NPT 90o elbow. The gas line can be rigid pipe or to make in- stallation easier, use a listed fl exible connector and/or copper tubing if allowed by local codes. Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN/CGA B149 installation codes. For USA installations follow local codes and/or the current National Fuel Gas Code, ANSI Z223.1.

When using copper or fl ex connectors use only approved fi ttings. Always provide a union so that gas lines can be easily disconnected for burner and/or valve servicing. Flare nuts for copper lines and fl ex connectors are usually considered to meet this requirement.

Important:Always check for gas leaks with a soapandwatersolutionorgasleakdetector. Do not use open flame for leak testing.

Note: Prior to any pressure testing of the gas supply piping system that exceeds test pressures of 1/2 psig, this appliance must be disconnected from the piping system. Iftestpressuresequalto orlessthan1/2psigareusedthen this appliance must be isolated from the piping system by clos- ingitsindividualmanualshut-off valve during the testing.

System Data - U37

For 0 to 4500 feet altitude

Burner Inlet Orifice Sizes:

Natural Gas Propane

 

Burner

#37

#52

 

 

 

 

 

 

Max. Input Rating

30,000 Btu/h

 

 

Min. Input Rating

15,000 Btu/h

 

 

 

 

 

 

 

Supply Pressure

 

 

 

 

Natural Gas

min. 5.0" w.c.

 

 

Propane

min. 12.0" w.c.

 

 

 

 

 

 

 

Manifold Pressure

 

 

 

 

Natural Gas

3.8"

+/- 0.2" w.c.

 

 

Propane

11"

+/- 0.2" w.c.

 

HIGH ELEVATION

This unit is approved in Canada for altitude 0 ft. to 4500 ft. (CAN/CGA-2.17-M91). For Natural Gas installations above 4500 ft. follow current CAN/CGA-B149.1.

AERATION

ADJUSTMENT

The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude.

Natural Gas:

1/4" open

Propane:

3/8" open

The aeration adjustment gears are located on the right side of the burner box and can be ac- cessed from the side or from the front when the louvers are removed.

To adjust the aeration: use the allen key to turn the turning gear which will adjust the air shutter. Open the air shutter for a blue fl ame or close it for a yellower fl ame. The factory setting should be sufficient for most installations.

Clockwise to open,

counter-clockwise to close.

Caution: Carbon will be produced if the air shutter is closed too much.

Note: Any damage due to carboning result- ing from improperly setting the aera- tion controls is NOT covered under warranty.

Note: Aeration Adjustment should only be performedbyanauthorizedRegency® Installer at the time of installation or service.

LOG SET

INSTALLATION

Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot operation.

The gas log kit contains the following:

a)02-65 Rear Log

b)02-56 Middle Left Log

c)02-44 Front Left Log

d)02-46 Left Top Log

e)02-45 Front Right Log

f)02-47 Center Log

g)02-48 Middle Right Log

h)

Embers

902-151

i)

Lava

902-154

The "02" refer numbers (i.e. 02-65) are

molded into the rear of each log.

1)Carefully remove the logs from the box and unwrap them. The logs are fragile, handle with care - do not force into position.

2)Sprinkle the embers on the left and right sides of the fi rebox base.

Embers.Embers

20

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove

Page 20
Image 20
Regency U37-LP1, U37-NG1 installation manual GAS Connection, High Elevation, Aeration Adjustment, LOG SET Installation

U37-LP1, U37-NG1 specifications

The Regency U37-NG1 and U37-LP1 are two innovative models that showcase advanced technology and superior engineering in the realm of HVAC (heating, ventilation, and air conditioning) systems. These units are designed to deliver optimal comfort while maximizing energy efficiency, making them ideal for both residential and commercial applications.

One of the standout features of the U37-NG1 is its use of a high-efficiency burner system, which ensures that every unit is capable of delivering substantial heating output while consuming minimal gas. This not only translates to lower utility bills for users but also aligns with sustainability goals by reducing carbon emissions. In terms of design, the U37-NG1 is compact and can be installed in a variety of settings, making it a versatile choice for many different environments.

The U37-LP1, on the other hand, is tailored for propane applications, making it perfect for areas where natural gas is inaccessible. It features a similar high-efficiency heating output, ensuring that it meets the demands of users without compromising on performance. The dual-fuel capability of the U37 series enhances its adaptability, allowing it to be used in a range of scenarios.

Both models are equipped with advanced control technologies, including programmable thermostats and smart connectivity features. Users can easily manage their heating systems through mobile apps, allowing for remote adjustments and real-time monitoring. This technology not only enhances user convenience but also promotes energy conservation by allowing users to adjust settings based on their lifestyle and preferences.

In terms of durability, the Regency U37 series boasts a robust construction designed to withstand various environmental conditions. With quality materials and expert craftsmanship, these units are built to last, reducing the need for frequent repairs or replacements.

Overall, the Regency U37-NG1 and U37-LP1 models combine cutting-edge technology with practical features to deliver an exceptional heating experience. Their commitment to energy efficiency, adaptability, and user-friendly controls positions them as leading options in the HVAC market, making comfortable living spaces more accessible while promoting environmentally responsible practices. Whether for home use or commercial properties, these systems offer reliability and performance tailored to the needs of modern users.