SAFETY LABEL
This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door.
NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Label for U37
Listed: GRAVITY DIRECT VENT WALL FURNACE
Certified for/Certifiée pour: CANADA AND U.S.A.
Tested to: CGA
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
Serial No./No de serie
313
DO NOT REMOVE THIS LABEL /
NE PAS ENLEVER CETTE ÉTIQUETTE
|
| FACTORYEQUIPPED FOR NATURALGAS: Model | ÉQUIPÉ À L'UISINE POUR GAZ NATURAL: | ||||
Model/Modele: | Min. supply pressure | 5.0" | WC/C.E. (1.24Kpa) | Pression d’alimentation minimum | |||
Manifold pressure High | 3.8" | WC/C.E. (0.947Kpa) Pression à la tubulure d’échappement élevée | |||||
Manifold pressure Low | 1.1" | WC/C.E. (0.27Kpa) | Pression à la tubulure d’échappement élevée | ||||
|
| ||||||
|
| Orifice size | #37 | DMS |
| Dimensions de l’orifice | |
|
| Altitude | ft/pi | L’altitude | |||
|
| Maximum Input | 30,000 | Btu/h | (8.79Kw/h) | Débit calorifique maximum selon | |
|
| Minimum Input | 15,000 | Btu/h | (4.39Kw/h) | Débit calorifique minimum selon | |
|
|
|
| ||||
|
| FACTORY EQUIPPED FOR PROPANE: Model | ÉQUIPÉ À L'UISINE POUR GAZ PROPANE: | ||||
|
| Min. supply pressure | 12" | WC/C.E. (3.00Kpa) | Pression d’alimentation minimum | ||
Model/Modele: | Manifold pressure High | 11" | WC/C.E. (2.74Kpa) | Pression à la tubulure d’échappement élevée | |||
Manifold pressure Low | 2.9" | WC/C.E. (0.72Kpa) | Pression à la tubulure d’échappement élevée | ||||
|
| ||||||
|
| Orifice size | #52 | DMS |
| Dimensions de l’orifice | |
|
| Altitude | ft/pi | L’altitude | |||
|
| Maximum Input | 30,000 | Btu/h | (8.79Kw/h) | Débit calorifique maximum selon | |
|
| Minimum Input | 15,000 | Btu/h | (4.39Kw/h) | Débit calorifique minimum selon | |
|
|
|
|
|
|
|
VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or the current
Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.
FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA
DOOR SEAL ADJUSTMENT: | Please check that door is properly sealed. |
| Periodic adjustment of latch may be required. |
|
Minimum Clearances
to Combustibles/
Degagement Minimum
Des Materiaux
Combustibles
B3" /76 mm
E
Min. Ceiling
Height from top of unit / Min. Plafond Hauteur en haut de l'appareil: 36" / 914 mm
For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.
For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances individual manual
The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.
4 |