Regency U37-LP1 Safety Label, Door Seal Adjustment, Please check that door is properly sealed

Models: U37-LP1 U37-NG1

1 36
Download 36 pages 8.33 Kb
Page 4
Image 4
SAFETY LABEL

SAFETY LABEL

This is a copy of the label that accompanies each ULTIMATE Rear Vent Direct Vent Free- standing Gas Stove. We have printed a copy of the contents here for your review. The safety label is located on the inside of the drop down pedestal door.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

Copy of Safety Label for U37

Listed: GRAVITY DIRECT VENT WALL FURNACE

Certified for/Certifiée pour: CANADA AND U.S.A.

Tested to: CGA 2-17-M91, ANSI Z21.88b-2003/CSA 2.33b-2003 REPORT NO. 476-1846-00 (Oct. 2000)

MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE

Serial No./No de serie

313

DO NOT REMOVE THIS LABEL /

NE PAS ENLEVER CETTE ÉTIQUETTE

 

 

FACTORYEQUIPPED FOR NATURALGAS: Model U37-NG1

ÉQUIPÉ À L'UISINE POUR GAZ NATURAL:

U37-NG1

Model/Modele:

Min. supply pressure

5.0"

WC/C.E. (1.24Kpa)

Pression d’alimentation minimum

Manifold pressure High

3.8"

WC/C.E. (0.947Kpa) Pression à la tubulure d’échappement élevée

Manifold pressure Low

1.1"

WC/C.E. (0.27Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

Orifice size

#37

DMS

 

Dimensions de l’orifice

 

 

Altitude

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

Maximum Input

30,000

Btu/h

(8.79Kw/h)

Débit calorifique maximum selon

 

 

Minimum Input

15,000

Btu/h

(4.39Kw/h)

Débit calorifique minimum selon

 

 

 

 

 

 

FACTORY EQUIPPED FOR PROPANE: Model U37-LP1

ÉQUIPÉ À L'UISINE POUR GAZ PROPANE:

 

 

Min. supply pressure

12"

WC/C.E. (3.00Kpa)

Pression d’alimentation minimum

U37-LP1

Model/Modele:

Manifold pressure High

11"

WC/C.E. (2.74Kpa)

Pression à la tubulure d’échappement élevée

Manifold pressure Low

2.9"

WC/C.E. (0.72Kpa)

Pression à la tubulure d’échappement élevée

 

 

 

 

Orifice size

#52

DMS

 

Dimensions de l’orifice

 

 

Altitude

0-4500

ft/pi

(0-1370m)

L’altitude

 

 

Maximum Input

30,000

Btu/h

(8.79Kw/h)

Débit calorifique maximum selon

 

 

Minimum Input

15,000

Btu/h

(4.39Kw/h)

Débit calorifique minimum selon

 

 

 

 

 

 

 

VENTING: Only for direct discharge without duct connection. This appliance must be installed in accordance with the manufacturer's installation instructions and with local codes, if any; if not, follow the current ANSI Z223.1 in the USA or the current CAN/CGA-B149 in Canada. For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

Electrical supply 115VAC, 1.13 A, 60 Hz. Not for use with solid fuel.

FPI Fireplace Products International Ltd., Delta, BC, Canada MADE IN CANADA / FABRIQUE AU CANADA

DOOR SEAL ADJUSTMENT:

Please check that door is properly sealed.

 

Periodic adjustment of latch may be required.

 

918-507

Minimum Clearances

to Combustibles/

Degagement Minimum

Des Materiaux

Combustibles

A7-1/2" /190 mm

B3" /76 mm

E 4-1/2" /114 mm

Min. Ceiling

Height from top of unit / Min. Plafond Hauteur en haut de l'appareil: 36" / 914 mm

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

4

U37-1 Regency® ULTIMATE Rear Vent Direct Vent Freestanding Gas Stove