INSTALLATION
CONVERSION KIT# 514-969 FROM NG TO LP
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Each Kit contains one LPG Conversion Kit and one DC Sparker Kit.
Conversion Kit Contains:
Qty. | Part # | Description |
1
1
1
1
1 | LPG Injector | |
|
| (Pilot Orifi ce) |
1
DC Sparker Kit Contains:
Qty. Part # | Description |
1
1
1
1
1
Black
2
0.500 in.
1
2
Black Oxide
1
1
1
Energizer En91
2
1
Ground 30 in.
Installation of LPG
Conversion Kit:
1)Shut off the gas supply.
2)Open the front door and carefully re- move the logs and lava rock.
3)Remove burner. See diagram below.
Note:
Use a magnetic type screwdriver if possible.
Pilot assembly is now accessible.
4)Pull off the pilot cap to expose the pilot orifi ce.
5)Unscrew the pilot orifi ce with the allen key; then replace with the LPG pilot orifi ce and the pilot cap, provided in the kit.
6)Remove burner orifi ce with a 1/2" wrench. Use another wrench to hold on to the elbow behind the orifi ce. Discard orifi ce.
Burner Orifi ce
7)Reinstall new burner orifi ce LPG stamped #52 and tighten.
8)Turn control knob to the “OFF” position.
9)Remove the black protection cap by hand from the
Fig. 1
17 |