The [Address] group box sets address bus conditions. The contents of an option that can be will change depending on the radio button selected. The [Data] group box sets the data bus conditions. The [Read/Write] group box sets the read/write cycle conditions.
Option Description
[Don’t care] check box Does not set address conditions.
[Address] radio button Sets the use of the normal address bus as break
conditions.
[Only program fetched address after]
radio button Sets a break after prefetched address execution as break
conditions.
[Address] edit box Sets the address bus value with a number or a symbol.
[Mask] edit box Sets a value to be masked when [User mask] is selected.
For masked bits, the break condition is satisfied for any
values.
Option Description
[Address] radio button All options can be set.
[Only program fetched address after]
radio button The [Address] option can be set.
Option Description
[Don’t care] check box No data conditions are set.
[Value] edit box Sets the data bus with a number.
[Low byte] radio button Sets data access size as the lower 8-bit access.
[High byte] radio button Sets data access size as the upper 8-bit access.
[Word] radio button Sets data access size as the word access.
Option Description
[Read/Write] radio button Sets the read/write cycle conditions as break conditions.
[Read] radio button Sets read cycles as break conditions.
[Write] radio button Sets write cycles as break conditions.
86