(e) When [Power supply is carried out. (MAX 300mA)] is not checked, the dialog box
shown in Figure 4.25 will be displayed.
Figure 4.25 Dialog Box of Power-on request message
When [Power supply is carried out. (MAX 300mA)] is not checked, turn on the power to
the user system.
(f) Enter the ID code printed on the flash memory.
Figure 4.26 [ID Code verification] Dialog Box
Note: Opening the [ID Code verification] dialog box in Writing Flash memory mode depends on
a target device. For details, refer to the additional document “Notes on Connecting the
xxxxx”.