Variable updating
For updating of the content of the variable that has been registered in the [Watch] window,
read the data after the break in user program execution. The realtime operation for the user
program is disabled because the user program is temporarily stopped.
5. Line Assembly
Input radix
Regardless of the Radix setting, the default for line assembly input is decimal. Specify H’
or 0x for the H8 series microcomputers and xxxxh for the R8C/Tiny, M32C and M16C
series microcomputers as the radix for a hexadecimal input.
6. Command Line Interface
Batch file
To display the message “Not currently available” while executing a batch file, enter the
sleep command. Adjust the sleep time length which differs according to the operating
environment.
Example: To display “Not currently available” during memory_fill
execution:
sleep d3000
memory_fill 0 ffff 0
File specification by commands
The current directory may be altered by file specifications in commands. It is
recommended to use absolute paths to specify the files in a command file so that the
current directory alteration is not affected.
Example: FILE_LOAD C:\Hew3\Tools\Renesas\DebugComp\Platform\E8\
E8R8C\TutorialR8C\Tutorial\Debug_R8C_E8_SYSTEM\Tutorial.x30
7. Memory Save During User Program Execution
Do not execute memory save or verifying during user program execution.
8. Load of Motorola S-type Files
This High-performance Embedded Workshop does not support Motorola S-type files with only
the CR code (H'0D) at the end of each record. Load Motorola S-type files with the CR and LF
codes (H'0D0A) at the end of each record.
9. [I/O] window
Display and modification
Do not change values in the [I/O] window because the emulator uses the address break
controller.
138
Note that the E8 emulator does not support the display of the invalid module in the [I/O]
window. For the H8/Tiny and H8/ Super Low Power series, the E8 emulator dose not
support the display of the bit information in the [I/O] window.