FEATURES OF THE RHFE-431FA UNITS
◆Clean Heating Forced Flue Type
◆Easy Operation
◆Sensible Temperature Control Feature
◆Comfortable Room Temperature Control and Display
◆Warm Air Outlet at Floor Level (Keeps Your Feet Warm)
◆Child Safety Lock
◆Room Temperature Setting Memory
◆Dirty Air Filter Indicator Lamp
◆
◆Humidifier Tray
◆Air Flow Directional Louvers
◆Direct Vent Easily Installed
◆Proportional Heating Variable Capacity
◆Hush! Quiet Operation
◆Modern Design Minimizes Floor Space Requirements
◆Failure Message Display
SAFETY DEVICES
Spark Safety Device: Automatically shuts unit down when there is an abnormal spark at time of ignition. Display lamps “LOW”, “60”, and “64” will activate if this happens.
Flame Failure Device: Activated when burner flame fails, indicator lamp “ON” flashes. If burner fails to ignite, indicator lamp “60” flashes. This prevents raw gas from being released.
Overheat Switch: This device automatically cuts the gas off if the heater exceeds a predetermined temperature. This is normally caused by an obstruction in front of the louvers, or a blocked fan filter. Indicator lamp “68” “ON” and the “FILTER” indicator lamp flash when overheat switch is activated.
Two Fusible Links: Backs up the overheat switch. If the fusible link cuts the unit off, a service call by an authorized person is required to replace the link. Indicator lamps “68” , “FILTER” and “ON” will flash.
– 1 –