Rinnai installation manual FEATURES OF THE RHFE-431FAUNITS, Safety Devices

Models: RHFE-431FA

1 60
Download 60 pages 14.62 Kb
Page 3
Image 3
FEATURES OF THE RHFE-431FA UNITS

FEATURES OF THE RHFE-431FASAFETY DEVICES UNITS

Clean Heating Forced Flue Type

Easy Operation One-Touch Ignition

Sensible Temperature Control Feature

Comfortable Room Temperature Control and Display

Warm Air Outlet at Floor Level (Keeps Your Feet Warm)

Child Safety Lock

Room Temperature Setting Memory

Dirty Air Filter Indicator Lamp

Energy-Saving Economy Setting

Humidifier Tray

Air Flow Directional Louvers

Direct Vent Easily Installed

Proportional Heating Variable Capacity

Hush! Quiet Operation

Modern Design Minimizes Floor Space Requirements

Failure Message Display

SAFETY DEVICES

Spark Safety Device: Automatically shuts unit down when there is an abnormal spark at time of ignition. Display lamps “LOW”, “60”, and “64” will activate if this happens.

Flame Failure Device: Activated when burner flame fails, indicator lamp “ON” flashes. If burner fails to ignite, indicator lamp “60” flashes. This prevents raw gas from being released.

Overheat Switch: This device automatically cuts the gas off if the heater exceeds a predetermined temperature. This is normally caused by an obstruction in front of the louvers, or a blocked fan filter. Indicator lamp “68” “ON” and the “FILTER” indicator lamp flash when overheat switch is activated.

Two Fusible Links: Backs up the overheat switch. If the fusible link cuts the unit off, a service call by an authorized person is required to replace the link. Indicator lamps “68” , “FILTER” and “ON” will flash.